VoIP Gateway Router

The Aqeri 97100 rugged VoIP Gateway Router supports eight FXS or FXO telephone conversations. Combine Voice over IP with with advanced Quality od Service (QoS) and full internet access and security features to provide best in class service and voice quality. This integrated access router and VoIP Gateway benefits both service providers and enterprise network administrators with a lower cost of ownership. This unit is built into a fully sealed aluminium chassis.

  

 

Functional specifications:
Voice Connectivity:        2-wire Loopstart, RJ-11/12
                                    Short haul loop 1.1 KM @3REN
                                    EuroPOTS (ETSI EG201 188)
                                    Caller-ID Type-1/2 FSK and ITU V.23/Bell 202 generation
 
Data Connectivity:          Dual 10/100 Full Duplex, Autosensing, Ethernet RJ-45 and SC Fiber interface
 
Fax and Modem Support: G.711 Fax- and Modem-Bypass, T.38 Fax relay (9.6 k, 14.4 k)
 
Voice Signalling:            H.323v4 : - RAS, H.225, H.245, - H.235 secure RAS.
 
IP Services:                   IPv4 router
                                    Static Routes, ICMP redirect (RFC 792), RIPv1, v2 (RFC 1058 and 2453)
                                    Static and dynamic NAT and NAPT
                                    DHCP server and Client
 
 
Physical characteristics:
Dimensions: 440(W) x 300(D) x 42(H)
Weight: 3 Kg
Colour: Green, optional any colour
 
Electrical specifications:
Power requirements: 18-36VDC
Power consumption: TBT
Connectors:       8x FXO RJ11
1x RJ45 Ethernet
1x SC Fiber Ethernet
1x DB9 Console port
1x Canon Chassis Bayonet DC IN
 
Environmental characteristics:
Temperature: Operating -20°C to +55° C
Humdity: 5% to 95% non condensing
Enclosure: IP54 (T)
Vibration: Operating 1G 10-1000Hz
Shock: Operating 10G, 11ms, ½ sine wave pulse
Altitude: Operating 3000M
EMI/RFI/EMC: MIL-STD-461
 
Designed to fulfil: MIL-STD-461/462 C / D, MIL-STD-810, EN61000-4-2 lev 4, EN 61000- 4-3 lev 3, EN61000-4-4 lev 3, 3, EN 61000-4-5 lev 1, EN 61000-4-6 lev 2, EN 61000-4-8 lev 3,
EN 55022 B, IEC 68-2-6, IEC 68-2-27, IEC 68- 2-29, IEC 68-2-31, IEC 68-2-32